Dual Pressure Exhaust Gas Boiler

Dual Pressure Exhaust Gas Boiler Related Information

Exhaust Gas Boiler on Ships - Marine Engineering

Exhaust gas boiler (EGB or EGE) or economiser described in this article is a smoke tube boiler with steam space, used for heat recovery from main engine exhaust gas. An illustration of the boiler is shown in figure below. The exhaust gas boiler is designed as a vertical boiler with a cylindrical shell surrounding the boiler tubes and water drum

Get a Quote

Dual fuel combustion in new dimensions - SAACKE

Due to its innovative character and the dimensions of the ship, this project posed a great challenge for everyone involved. SAACKE GmbH impressed with its dual fuel solution consisting of two FMB-VM boiler plants, each with a SKVG 50 burner, electrical control equipment, fuel supply modules for gas and oil and four exhaust gas boilers for heat recovery.

Get a Quote

Alfa Laval - Aalborg OC

2020-11-17 · Aalborg OC is a high performance, combined oil and exhaust gas-fired boiler, with a 0.75-5 t/h capacity of the oil-fired section at 9 bar (g) design pressure. Aalborg OC is a vertical, cylindrical boiler with an exhaust gas section consisting of bare smoke tubes while the oil-fired section features pin tubes in the convection section

Get a Quote

DUAL FIRED COMBI BOILER - IBCBoiler.com

2020-8-16 · Max Gas Pressure (Nat. Gas or Propane) – inch w.c. 14 14 Power (120Vac/60Hz) - Watts @ full fire with internal pump 120 120 Weight (empty) – lbs/Kg 85 / 39 84 / 38 Pressure vessel water content – USG/Liters 0.5/1.9 0.19/.72 Max boiler flow rate - USgpm 10 12 Min boiler flow rate - USgpm 2 2

Get a Quote

WASTE HEAT AND EXHAUST GAS BOILERS

2019-2-4 · Exhaust gas can flow vertically or horizontally, process fluid can be steam, hot water or thermal oil. Heat recovery equipment can incorporate one or more banks of tubes with selected geometry to suit specific applications. Steam boiler plant can be designed for single or dual pressure

Get a Quote

Composite Marine Boilers from SAACKE

The exhaust gas section is designed with plain smoke tubes. The special spherical shape of the furnace top plate gives an increased stability against ship vibrations and protects this part of the boiler against partial overheating, because residues in the boiler water are led to the boiler bottom before they can accumulate on the furnace top plate.

Get a Quote

EPCB High Quality Nature Gas And Diesel Oil Dual

EPCB High Quality Nature Gas And Diesel Oil Dual Fuel Boiler Boiler Features: 1. This series boiler adopts vertical through flow and three-pass furnace. 2. The burner is down-fired type. 3. The flame can completely spread from the top down to make burning full. 4.

Get a Quote

Thermo Efficiency System (TES)

2015-11-18 · Exhaust gas HP LP Exh. gas boiler sections: Surplus valve Hot well 2. Dual-pressure steam system When using the dual-pressure steam system, it is not possible to install an exhaust gas low-pressure preheater section in the exhaust gas boiler, be-cause the exhaust gas boiler outlet temperature otherwise would be too low and increase the risk of

Get a Quote

Exhaust Gas Boilers And Economisers for Marine

2020-7-13 · On vessels with an exhaust economiser by pass valve, water temperature is a critical factor in preventing condensation and acid formation on the gas side. The minimum temperature of 140 degree C should be kept, when running with the exhaust gas bypassing the economiser. iii) Operation 1) Exhaust gas boiler circulation must be maintained at all

Get a Quote

SECTION 235216 - CONDENSING BOILERS

A.Description: Boiler shall be either natural gas, propane or dual fuel (nat. gas/propane) fired, fully condensing, fire tube design. Power burner shall have full modulation, discharge into a positive or negative pressure vent and the minimum firing rate shall not exceed the following per model:

Get a Quote

Design methodology of heat recovery steam

The present research is focused on the design of a HRSG, including a dual-pressure steam generator cycle that is intended for use in a typical gas turbine unit having a power output of 60 MW. The results show that the maximum heat transfer occurs in the evaporator section for high-pressure levels, and in the economizer section for low-pressure

Get a Quote

GAS FIRED BOILER SC-3000/SC-4000 Natural

2019-3-15 · Gas • Use a lock-up type regulator. • Minimum gas inlet pressure 4.5" wc • Maximum gas inlet pressure 14" wc Electrical • Verify power requirements to boiler. • Check all electrical connections for tightness as connections may come lose during shipping. Venting • Maintain exhaust pressure from -.04" wc to +.22" wc Hydronics

Get a Quote

SAACKE case study: Dual fuel combustion in new

SAACKE GmbH impressed with its dual fuel solution consisting of two FMB-VM boiler plants, each with a SKVG 50 burner, electrical control equipment, fuel supply modules for gas and oil and four exhaust gas boilers for heat recovery.

Get a Quote

China Gas/Oil/Dual Fuel 350kw Pressure Hot Water

5) The hot oil boiler is characterized by countercurrent heat exchange, and the temperature difference between the combustion exhaust gas temperature and the heat transfer oil outlet is below 30 °C. 6) The excellent structure of the hot oil boiler is mainly operated at a lower pressure, and the operating temperature below 450 °C is obtained

Get a Quote

Combined cycle power plant - Wikipedia

2020-9-3 · Transfer of heat energy from high temperature exhaust gas to water and steam takes place by a waste heat recovery boiler in the bottoming cycle. During the constant pressure process 4-1 the exhaust gases in the gas turbine reject heat. The feed water, wet and super heated steam absorb some of this heat in the process a-b, b-c and c-d.

Get a Quote

DUAL FIRED COMBI BOILER - IBCBoiler.com

2020-8-16 · Max Gas Pressure (Nat. Gas or Propane) – inch w.c. 14 14 Power (120Vac/60Hz) - Watts @ full fire with internal pump 120 120 Weight (empty) – lbs/Kg 85 / 39 84 / 38 Pressure vessel water content – USG/Liters 0.5/1.9 0.19/.72 Max boiler flow rate - USgpm 10 12 Min boiler flow rate - USgpm 2 2

Get a Quote

Effect of Gas Turbine Exhaust Temperature, Stack

2015-1-8 · Keywords: Gas Turbine, Steam Turbine, exhaust temperature, stack temperature, ambient temperature, Combine cycle. Introduction Combine cycle plant is used for large base-load generating stations. The ultimate aim is to reduce the cost of power generation. In dual pressure

Get a Quote

US5660799A - Exhaust gas boiler - Google Patents

pressure exhaust gas low denitrator gas boiler Prior art date 1993-09-17 Legal status (The legal status is an assumption and is not a legal conclusion. Google has not performed a legal analysis and makes no representation as to the accuracy of the status listed.) Expired - Lifetime Application number US08/432,210 Inventor Toshiki Motai Norihisa

Get a Quote

exhaust gas - NauticExpo

Aalborg OC is a high performance, combined oil and exhaust gas-fired boiler with a high capacity. The product is quick and easy install. Aalborg OC is a high performance, combined oil and exhaust gas-fired boiler, with a 0.75-5 t/h capacity of the oil-fired section at 9 bar (g) design pressure.

Get a Quote

Boiler Economizer Exhaust Heat Recovery Systems

The vertical RTR unit (upper-right photo) replaced a failed competitor's unit and was constructed to be a replacement fit and offer greater performance. ASME designed at 750 PSIG this RTR is rated for a 150,000 lb/hr steam boiler. With an exhaust gas flow rate of more than 36,000 SCFM, it saves the end user over $450,000 each year in fuel costs.

Get a Quote